Books
[1] Vaughan N (2016), "Biomedical Engineering for Orthopaedics", Neil Vaughan Eds. OmicsGroup, In Preparation. http://www.esciencecentral.org/ebooks/biomedical-engineering-for-orthopaedics/
Theses
[1] Vaughan N
(2014), "Patient-specific Epidural for Training and Assessment",
Bournemouth University, PhD Thesis. http://staffprofiles.bournemouth.ac.uk/display/thesis/174098
[2] Vaughan N
(2011), "Development of an Epidural Simulator for Training and
Assessment", Bournemouth University, MSc Thesis.
[3] Vaughan N (2006), "Face recognition in Real-time Video", Brunel University Dept. of Information Systems and Computing, Supervisor: Yongmin Li, BSc (Hons) Thesis.
Book Chapter Publications
[1] Dubey VN, Vaughan N, Wee MYK, Isaacs R, (2013), "Biomedical Engineering in Epidural Anaesthesia Research," Book Chapter 15, Practical Applications in Biomedical Engineering, ISBN 978-953-51-0924-2. http://www.intechopen.com/books/practical-applications-in-biomedical-engineering/biomedical-engineering-in-epidural-anaesthesia-research Over 2000 international downloads.
[2] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2014) "Hybrid Epidural Simulator: Augmented Physical Simulation with Virtual Reality Underlays," Nova books.
[3] Vaughan N, (2014), "Patient-specific Epidural Simulator for Training and Assessment", PhD Thesis, Bournemouth University.
Patents
[1] Vaughan
N, Dubey, VN, Hickish, T, Cole J, (2016, May 16th)
PCT/GB2016/051405, "Neuropathy Assessment Device", European Patent
Office, BU Innovations Limited & Bournemouth University Higher Education
Corporation.
[2] Vaughan
N, Dubey, VN, Hickish, T, Cole J, (2015, May 18th) "Neuropathy
Assessment Device" patent filed at the UK Intellectual Property Office.
Patent application number 1508513.7.
Journal Article Publications
[1] Vaughan, N., Gabrys, B., (2017, Jan) Skill
Classification in Adaptive Virtual Training, Artificial Intelligence in
Medicine (AIIM) (Impact 2.3), In
Preparation.
[1] M Mediouni, D Schlatterer, Amal Khoury, T von Bergen, S Shetty, M Arora, A Dhond, N Vaughan, A Volosnikov, (2017, Feb) Optimal Parameters to Avoid Thermal Necrosis During Bone Drilling: A Finite Element Analysis, Wiley Journal of Orthopaedic Research (JOR)(Impact 2.2), Accepted 2017, In Print. http://onlinelibrary.wiley.com/doi/10.1002/jor.23542/epdf
[2] Vaughan N, Dubey VN (2017, Sep) Interpreting Ultrasound
Images For Accurate Epidural Needle Insertion, ASME Journal of Medical Devices,
accepted, DMD2017-3494, 11(3), In Print.
[3] Vaughan N, Dubey VN (2017, Sep) Virtual Hip Replacement
Simulator For 3D Printed Implants, ASME Journal of Medical Devices, accepted,
DMD2017-3496, 11(3), In Print.
[4] Vaughan N, Gabrys B, (2016, July) Comparing and
combining time series trajectories using Dynamic Time Warping, Elsevier Procedia Computer Science,96,
p465-474. http://www.sciencedirect.com/science/article/pii/S187705091631907X
[5] Vaughan N, Gabrys B, Dubey NV, (2016) An Overview of
Self-Adaptive Technologies Within Virtual Reality Training, Elsevier Computer
Science Review, 22, p65-87. http://www.sciencedirect.com/science/article/pii/S1574013716300259
[6] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2016, Aug)
Mechanism For Adaptive Virtual Reality Feedback, Journal of Medical Devices, April 2016, 10(3), 030951. http://medicaldevices.asmedigitalcollection.asme.org/article.aspx?articleID=2542284
[7] Mediouni M, Vaughan N, Shetty SH, Arora M, Volosnikov
A, Khoury A. (2016) How Challenging is the 'Scaling Up' of Orthopaedic
Simulation? Peertechz Journal of Orthopedics and Rheumatology, 1(1): 012-014. http://www.peertechz.com/Orthopedics-Rheumatology/pdf/PJOR-1-103.pdf
[8] Isaacs,
R., Wee, M.Y.K., Dubey, V. and Vaughan, N., 2015. A survey of trainees'
perspectives on epidural training in the United Kingdom. Global Anesthesia and
Perioperative Medicine. doi: 10.15761/GAPM.1000130.
http://oatext.com/A-survey-of-trainees-perspectives-on-epidural-training-in-the-United-Kingdom.php
[9] Vaughan N, Dubey VN, Wainwright TW, Middleton RG,
(2016, Feb) A Review of Virtual Reality Based Training Simulators for
Orthopaedic Surgery. Medical Engineering & Physics, 38(2), p59-71. (Impact
2.2) http://www.sciencedirect.com/science/article/pii/S1350453315002799
[10] Vaughan N, Dubey VN, (2015) Surface Mesh Density
Extraction of Orthopedic MRI with HSV Filtering, ASME Journal of Medical Devices, 9(3), 030949, https://medicaldevices.asmedigitalcollection.asme.org/article.aspx?articleID=2398373
[11] Vaughan, N., Dubey, V.N., Wee, M.Y.K. and Isaacs, R.,
(2015). Haptic feedback from human tissues of various stiffness and
homogeneity. Advances in Robotics
Research International Journal, 1 (3), 215-237. DOI:
10.12989/arr.2015.1.3.215 http://www.techno-press.org/download.php?journal=arr&volume=1&num=3&ordernum=3
[12] R Isaacs, M Wee, B Parker, V Dubey, N Vaughan, (2014,
Sept) "Measurement of epidural insertion pressures in laboring women of
varying body mass indices and imaging of the lumbar spine to develop a
high-fidelity epidural simulator for training" Anaesthesia 69 (s4), 84-84, (Impact
4.2) http://onlinelibrary.wiley.com/doi/10.1111/anae.12866/abstract. http://onlinelibrary.wiley.com/doi/10.1111/anae.12866/pdf.
[13] Vaughan, N., Dubey, V. N., Wee, M. Y., & Isaacs, R.
(2014). Parametric model of human body shape and ligaments for patient-specific
epidural simulation. Artificial
intelligence in medicine (AIIM) Journal (Impact 1.63 62(2), p129-140.) http://www.sciencedirect.com/science/article/pii/S0933365714001006
[14] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2014),
"Device to accurately place Epidural Tuohy needle for Anesthesia
Administration", Mechanical Sciences
Journal, Copernicus, Special Issue:
Design of medical devices: creative solutions by young researchers, vol 5, pp.
1-6. http://www.mech-sci.net/5/1/2014/ms-5-1-2014.html
[15] MYK Wee, R Isaacs, B Parker, N Vaughan, V Dubey (2014,
May) Measurement of epidural insertion pressures in labouring women of varying
body mass indices Intl. Journal of
Obstetric Anaesthesia (IJOA), 23, Proceedings of the OAA meeting 2014, Supplement 1, S1-S62, S9, http://www.obstetanesthesia.com/article/S0959-289X(14)00056-9/pdf.
[16] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2014, Apr)
'Virtual Reality Simulation Based Assessment Objectives For Epidural Training',
Journal of Medical Devices, 8(2), 020948. http://tribology.asmedigitalcollection.asme.org/article.aspx?articleid=1876518
[17] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2014, Apr)
"Epidural Pressure Measurements from Various BMI Obstetric Patients",
Journal of Medical Devices, 8(3), 030938 http://medicaldevices.asmedigitalcollection.asme.org/article.aspx?articleid=1841571.
[18] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2014, Apr)
"Synthetic Methods for Ultrasound-Guided Epidural Insertion
Simulation", Journal of Medical
Devices, 8(2), 020946.
[19] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2013),
"Towards a realistic in-vitro experience of epidural Tuohy needle
insertion", Proceedings of the Institution of Mechanical Engineers, Part
H: Journal of Engineering in Medicine
(JEIM), vol 227(7), pp.767-777. (Impact
1.32) http://pih.sagepub.com/content/early/2013/04/03/0954411913483428.abstract
[20] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2013), "A
review of epidural simulators: where are we today?" Medical Engineering & Physics (MEP) Journal, vol 35(9), pp.1235-50. (Impact 2.2) http://www.sciencedirect.com/science/article/pii/S135045331300057X
[21] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2013),
"Real Time Length Measurement of Tuohy Needle during Insertion", IET Science, Measurement & Technology
Journal, vol 7(4), pp.215-222.
[22] Isaacs R, Wee MYK, Dubey VN, Vaughan N, (2013, May),
"A pilot study to measure the insertion force of a Tuohy needle in a
porcine spine", Proceedings of Obstetric Anaesthesia 2013, May 23-24 2013,
Bournemouth, Oral Presentation O4, Oral Presentation O4, International Journal of Obstetric Anaesthesia (IJOA), 22, pp.
S7-S8. http://download.journals.elsevierhealth.com/pdfs/journals/0959-289X/PIIS0959289X13000526.pdf
[23] Vaughan, N., Dubey, V.N., Wee, M.Y.K. and Isaacs, R.,
(2013, April). Epidural Simulation for Patients of Various BMI and Body Shapes.
Journal of Medical Devices, 7(3),
030924. http://fuelcellscience.asmedigitalcollection.asme.org/article.aspx?articleid=1709363
[24]
Vaughan, N.,
Dubey, V.N., Wee, M.Y.K. and Isaacs, R., (2012, April). Advanced epidural
simulator with 3D flexible spine and haptic interface. Journal of Medical
Devices, 6 (1), 017524. http://appliedmechanics.asmedigitalcollection.asme.org/article.aspx?articleid=1916934
[25]
Vaughan, N., 2006. Robotic Autonomous Pathfinding.
Brunel University Department of Information Systems and Computing.
Conference Publications
[1] Vaughan N, Dubey VN (2017) Interpreting Ultrasound
Images For Accurate Epidural Needle Insertion, Design of Medical Device Conference, ASME Journal of Medical Devices,
accepted, DMD2017-3494, 11(3), Minneapolis USA.
[2] Vaughan N, Dubey VN (2017, Sep) Virtual Hip Replacement
Simulator For 3D Printed Implants, Design of Medical Device Conference, ASME Journal of Medical Devices, accepted,
DMD2017-3496, 11(3), Minneapolis USA.
[1] Vaughan N, Gabrys B, (2016, July) Comparing and
combining time series trajectories using Dynamic Time Warping, KES 2016 - 20th International Conference on
Knowledge-Based and Intelligent Information & Engineering Systems ,
York .
[2] Vaughan, N. (2016, Jan) Visual Navigation in Simulated
Pigeons, Artificial Life 2016, MIT Press. https://mitpress.mit.edu/sites/default/files/titles/free_download/9780262339360_ALIFE_2016.pdf
[3] Vaughan
N, Dubey VN, (2016) Hip replacement simulator for predicting dislocation risk, Intl. Design, Engineering & Technical
Conference, Paper59286, Charlotte, USA.
[4] Vaughan
N, Dubey VN, Hickish T, Cole C,(2016) Peripheral Neuropathy Point-Of-Care
Testing (Poct) With Smartphone App , Intl.
Design, Engineering & Technical Conference, Presentation, Charlotte,
USA.
[5] Vaughan N, Dubey VN, Wee MYK, Isaacs R, (2016)
Mechanism For Adaptive Virtual Reality Feedback, Design of Medical Devices Conference, April 2016.https://medicaldevices.asmedigitalcollection.asme.org/article.aspx?articleID=2542284
[6] Vaughan, N. (2015) Simulated Robotic Autonomous Agents
with Motion Evolution. In: Artificial
Life (ECAL): MIT Press, pp27.www.cs.york.ac.uk/nature/ecal2015/late-breaking/ecal2015-late-breaking-proceedings.pdf
[7]
Vaughan N, "Swapping Algorithm and Meta-heuristic
Solutions for Combinatorial Optimization n-Queens Problem", IEEE, Science and
Information Conference, 2015, July 28th 2015, London.http://ieeexplore.ieee.org/abstract/document/7237132/
[8]
Vaughan N, Dubey VN, " Surface Mesh Density
Extraction of Orthopedic MRI with HSV Filtering," ASME DMD2015, Design of Medical Devices Conference (DMD2015), April
2015, Minneapolis, Accepted, DMD2015-8739.
[9]
Vaughan N, Dubey VN, Wainwright TW, Middleton, RG, "Can
virtual-reality simulators assess experience and skill level of orthopaedic
surgeons?", IEEE, Science and Information Conference, 2015, July 28th 2015, London.http://ieeexplore.ieee.org/abstract/document/7237133/
[10]
Vaughan N, Dubey VN, Wainwright TW, Middleton, RG, "Does
virtual-reality training on orthopaedic simulators improve performance in the
operating room?", IEEE, Science and Information Conference, 2015, July 28th 2015, London.http://ieeexplore.ieee.org/document/7237125/
[11]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Body Shape and Size Modelling Using Regression Analysis
and Neural Network Prediction."
DETC2014-35427, Proceedings of the ASME 2014 Biomed
Conference, IDETC/CIE 2014,
August 17-20, 2014, Buffalo, NY, USA. http://proceedings.asmedigitalcollection.asme.org/proceeding.aspx?articleid=2090693
[12]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Spine flexion and extension modelling using patient
x-ray data" DETC2014-35427,
Proceedings of the ASME 2014 Biomed Conference, IDETC/CIE 2014, August 17-20, 2014, Buffalo, NY,
USA.
[13]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "In-Vivo Obstetric Pressure Measurements For
Patient-Specific Epidural Simulator"
DETC2014-35427, Proceedings of the ASME 2014 Computers and
Information in Engineering Conference, IDETC/CIE 2014, August 17-20, 2014, Buffalo, NY,
USA.
[14]
Wee MYK, Isaacs RA, Parker B, Vaughan N, Dubey VN,
"Measurement of epidural insertion pressures in labouring women of varying
body mass indices (BMIs)", Proceedings
of Obstetric Anaesthesia 2013, Int.
Journal Obsetric Anaesthesia, May 23-24 2014, Dublin.
[15]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Epidural
Pressure Measurements from Various BMI Obstetric Patients," ASME DMD2014, Design of Medical Devices
Conference (DMD2014), DMD2014-3637, April 7-10 2014, Minneapolis USA.
[16]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Synthetic
Methods for Ultrasound-Guided Epidural Insertion Simulation," ASME DMD2014, Design of Medical Devices Conference
(DMD2014), DMD2014-3638, April 7-10 2014, Minneapolis.
[17]
Vaughan N, Dubey VN, Wee MYK, Isaacs R,'VR Simulation Based
Assessment Objectives For Epidural Training,' ASME DMD2014, Design of Medical Devices Conference (DMD2014),
DMD2014-3639, April 7-10 2014, Minneapolis.
[18]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Artificial
Neural Network to Predict Patient Body Circumferences and Ligament
Thicknesses" Proceedings of the ASME
2013 Computers and Information in Engineering Conference, IDETC/CIE 2013
August 4-7, 2013, Portland, OR, USA.
[19]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Heterogeneous
Tissue Layer Deformation with Haptic Feedback" Proceedings of the ASME 2013 Computers and Information in Engineering
Conference, IDETC/CIE 2013 August 4-7, 2013, Portland, OR, USA
[20]
Vaughan N, Dubey VN, Wee MYK,Isaacs R, "Video Tracking
of Tuohy Needle for an Enhanced Epidural Simulator User Interface" Proceedings of the ASME 2013 Computers and
Information in Engineering Conference, IDETC/CIE 2013 August 4-7, 2013,
Portland, OR, USA
[21]
M.Y.K. Wee, R. Isaacs, N. Vaughan, V.N. Dubey, Measurement Of
Epidural Insertion Pressures In Labouring Women Of Varying BMIs, 18th Asean Congress of Anaesthesiologists,
Singapore, 31 Oct 2013. https://www.oaa-anaes.ac.uk/assets/_managed/cms/files/Meeting%20Docs/2014/IJOA%202014%20supplement%20full%20abstracts%20S.7%20-%20S.62.pdf .
[22]
R. Isaacs , M.Y.K. Wee, N. Vaughan, V.N. Dubey, "Epidural
Insertion Pressures In Labouring Women,"
Association for Simulated Practice in Healthcare, Harrogate 19th
Nov 2013.
[23]
RA Isaacs, MYK Wee, VN Dubey, N Vaughan, "A pilot study
to measure the insertion force of a Tuohy needle in a porcine spine to inform
the conduct of a clinical study to measure epidural insertion force in
labouring women." Proceedings of
Obstetric Anaesthesia 2013, Int.
Journal Obsetric Anaesthesia, May 23-24 2013, Bournemouth. http://www.obstetanesthesia.com/article/S0959-289X(13)00052-6/pdf
[24]
RA Isaacs, MYK Wee, VN Dubey, N Vaughan, "A survey of
Epidural training practices in the UK", Proceedings of Obstetric Anaesthesia 2013, May 23-24 2013,
Bournemouth.
[25]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Epidural
Simulation for Patients of Various BMI and Body Shapes," ASME DMD2013, Design of Medical Devices
Conference (DMD2013), April 8-11 2013, Minneapolis.
[26]
N. Vaughan, V.N. Dubey, M.Y.K. Wee, R. Isaacs, "Epidural
Needle Length Measurement by Video Processing," IET 2012 IPR Image Processing Conference, London 2012, 3-4 July.
[27]
Vaughan N, Dubey VN, Wee MYK, Isaacs R, "Haptic
Interface on Measured Data for Epidural Simulation," Proceedings of the ASME 2012 Computers and Information in
Engineering Conference, IDETC/CIE 2012 August 12-15, 2012, chicago, IL, USA
[28]
Vaughan N, Dubey VN, Wee MYK,Isaacs R, "Virtual Reality
based Enhanced Visualization of Epidural Insertion," Proceedings of the ASME 2012 Computers and Information in Engineering
Conference, IDETC/CIE 2012 August 12-15, 2012, Chicago, IL, USA
[29]
Vaughan N, Dubey VN, Wee M, Isaacs R. "Advanced Epidural
Simulator with 3D Flexible Spine and Haptic Interface." ASME Journal of
Medical Devices, Proceedings of DMD2012
Design of Medical Devices Conference, Minnesota. 2012.
[30]
Vaughan N, Dubey VN, Wee M, Isaacs R. "Measuring Tuohy
needle insertion force on a porcine spine." 6th International Conference on Bioinformatics and Biomedical
Engineering, Shanghai, China. May 2012